Koolance RP-1000SL Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Komputerowe chłodzenie cieczą Koolance RP-1000SL. Koolance RP-1000BK Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954
Other Technology Pending U.S. & World-Wide Patents
Superior Liquid Cooling Systems
®
English v1.02
PC4-1000 & RP-1000 Based Systems
Users Manual
www.koolance.com
ISO
9001
Printed in Korea
PC4-1000 & RP-1000 Based Systems
Users Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - User’s Manual

Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954Other Technology Pending U.S. & World-Wide PatentsSuperior Liquid Cooling Sys

Strona 2

5User ManualLED Display PanelModesThe PC4/RP-1000 offers seven display options. All are reached by continually pressing the SET button:1. Temperature

Strona 3

6Alarm & Shutdown SettingsBy default, the Koolance audio alarm will sound if any sensor reaches 55ºC (131ºF). When the system alarm sounds, the ap

Strona 4 - Table of Contents

7User ManualChapter2Connecting PC4-1000 Systems

Strona 5 - Required Tools

8Power ConnectionYou may begin the installation of your Koolance system by mounting a power supply in the chassis. With 3 radiator fans, the liquid co

Strona 6 - Chapter1

9User ManualCAUTION: The Power Connection is vital to system operation. A 12V 4-pin plug from the power supply must remain connected to the cooling sy

Strona 7

101010101010 Connecting PC4-1000 SystemsConnected Radiator & ReservoirConnected Radiator & ReservoirDepending on the cooling blocks (“cooler

Strona 8

11User ManualThe maximum number of coolers allowed in a system will depend upon your specifi c thermal requirements and hose confi guration. It is not u

Strona 9 - Component Diagram

12Each tubing connection uses a threaded compression fi tting (“hose screw”) to keep it secure. To connect these components:Connecting HosesThread a ho

Strona 10 - LED Display Panel

13User ManualDisconnecting HosesHoses are designed to snug fi rmly around the nozzle. If you need to remove a hose for any reason, it may not pull off

Strona 11

14Nozzles and tubing must be installed onto both the Radiator and Reservoir/Pump unit.To reach the Radiator nozzle sockets, it is generally easiest to

Strona 12 - Chapter2

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Strona 13 - Power Connection

15User ManualFinally, connect the 3-pin Radiator fan plug to either connection labeled “Fan” on the Reservoir/Pump unit and replace the screws on the

Strona 14 - ATX Power Switch

16Hose LengthsBefore installing your liquid coolers, appropriate lengths of tubing must be cut to connect each device. It may be easier to temporarily

Strona 15

17User ManualContinue connecting all of your coolers in the system until there are no longer any open tube ends.Liquid CoolersYou should now install t

Strona 16

18Chapter3Filling & MaintenanceFilling & MaintenanceWARNING: The RP-1000’s powerful single pump can not be run “dry” for any period of time. N

Strona 17 - Connecting Hoses

19User ManualTesting & FillingOnce all of the coolers have been connected, the system can be fi lled with coolant. The refi ll plug is located on to

Strona 18 - Disconnecting Hoses

20Do not overfi ll the reservoir. It is recommended to keep paper towels on hand just in case. The liquid coolant should be fi lled up to about 6mm (1/4

Strona 19 - Reservoir/Pump

21User ManualUnder normal circumstances, the liquid coolant does not require replacement. However, if it becomes contaminated, unclear, or signifi cant

Strona 20

22We hope your Koolance system will provide you with years of reliable cooling performance. To help avoid unnecessary RMA issues, we have prepared thi

Strona 21 - Hose Lengths

23User Manualbe malfunctioning. Please visit our support web page for more information.Verify that the pump is operating (see Troubleshooting #1), and

Strona 22 - Liquid Coolers

248. The LED Display Panel shows 5 - 0 or 5 - 5...5 - 0 (“S - O”): Sensor open. This indicates a temperature sensor can not be detected for a given ch

Strona 23 - Chapter3

iiWARNING: The Koolance liquid & coolant pack contain chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICALS

Strona 24 - Testing & Filling

25User ManualLimited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defe

Strona 25

iiiUser ManualTable of ContentsIntroduction 1Component Diagram ...

Strona 26

ivfl at-head screw driverphillips-head screw driverpliersscissorsRequired ToolsDuring installation, you may need the following tools:long-nose pliers

Strona 27 - Troubleshooting

1User ManualChapter1Introduction

Strona 28

2 Congratulations on your purchase of a Koolance system!As the most sophisticated product of its kind, Koolance offers many unique features found now

Strona 29

3User ManualEvery Koolance system includes built-in hardware safety features. Our proprietary power control board constantly monitors liquid temperatu

Strona 30 - Disclaimer

4 IntroductionComponent DiagramReservoirRadiator Cooling FansUnderneath: Radiator(Primary Heat Exchanger)Power Circuit BoardRadiator - The primary

Komentarze do niniejszej Instrukcji

Brak uwag